Ex flow heaters (industry) for outputs up to 30 kW (AH) and 50 kW (AHA) and for heating flowing liquid and gaseous media.
Our CSN® industrial flow heaters (AH) offer compact solutions for outputs of up to 30 kW and are ideal for heating flowing liquid and gaseous media. For even higher requirements, our CSN® Ex instantaneous water heater (AHA) is available, offering outputs of up to 55 kW. Both models enable efficient heating in potentially explosive environments. The AHA series can alternatively be equipped with integrated temperature monitoring to ensure additional safety.
Authorisation
Zone 1, Zone 21
Certification
ATEX, IECEx
Optional: Peso, CCC, EAC
Temperature class
T1 to T6
Ambient temperature range
Standard -40°C to +40°C
Power (kW)
0.2 to 30 (AH)
0.2 to 55 (AHA)
Voltage (V)
up to 1000
Protection class
IP 66
Medium
Liquid and gaseous
Process data
Medium, pressure and temperature according to specification
Housing / inlet and outlet nozzles
Flange connections and others
Heating elements
Tubular heaters
High-performance cartridge heaters
Heating element materials
1.4404 (AISI 316L); 1.4541 (AISI 321); 1.4571 (AISI 316 Ti);
1.4876 (Incoloy 800); 2.4858 (Incoloy 825)
Material of connection cover
Steel / aluminium (painted/powder-coated)
Installation length of heating elements (mm)
300 - 3500 for tubular heaters,
up to 6000 for high-performance cartridge radiators
Temperature monitoring
AH: without (standard); optional: external temperature controller, external temperature limiter, external sensors
AHA: without (standard); optional: external temperature controller,
internal/external temperature limiter, internal/external sensors
Execution
94F = for liquids
94GB = for gases, Ex zone on heating element
94GN = for gases, no Ex zone on the heating element
Customised versions on request
Andreas Hagedorn
+49 (0) 2392 692-30
andreas.hagedorn@schniewindt.de
Robin Gerecht
+49 (0) 2392 692-750
robin.gerecht@schniewindt.de